Aerosol evaluation difficulties due to particle deposition on filter holder inner walls

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017841
003  MAP
005  20080418115216.0
007  hzruuu---uuuu
008  940310e19900801gbr|||| | |00010|eng d
035  ‎$a‎6800000007
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
24510‎$a‎Aerosol evaluation difficulties due to particle deposition on filter holder inner walls‎$c‎M. Demange... [et al.]
520  ‎$a‎The analysis of aerosol particles collected on aerosol samplers is most generally performed on the filter alone. A chemical digestion method, performed directly inside the filter cassette, avoids any external pollution or sample loss due to handling. A systematic comparison of these two methods, performed on different industrial sites, demonstrates that a sometimes significant fraction of the sampled aerosol deposits on the inner cassette walls, resulting in severe underestimation of the occupational hazard with the first method. A review of published laboratory studies clearly indicates that every particle entering the cassette is part of the sample
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080549534‎$a‎Aerosoles
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080621186‎$a‎Control de la contaminación
65011‎$0‎MAPA20080559670‎$a‎Muestreador
65011‎$0‎MAPA20080543969‎$a‎Filtros
65011‎$0‎MAPA20080551797‎$a‎Muestreos
7001 ‎$0‎MAPA20080023027‎$a‎Demange, M.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 4, August 1990 ; p. 399-403