Búsqueda

Method for the evaluation of the permeation characteristics of protective glove materials

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020022</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120044.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940623e19880601usa||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013449</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080167295</subfield>
      <subfield code="a">Jencen, David A.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Method for the evaluation of the permeation characteristics of protective glove materials</subfield>
      <subfield code="c">David A. Jencen and James K. Hardy</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A method is described to evaluate the permeation characteristics of glove materials by chemical solvents. The collecting medium is continuously monitored by a flame ionization detector of a gas chromatographic. Inmediately following a steady-state condition, quantitative data are acquired on-line by a computer. A two-position GC sampling valve and computer-controlled data acquisition and analysis require minimal operator attention. A modification of the procedure which allowed the determination of the effect of temperature on permeation for 4 glove/solvent pairs was evaluated</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613839</subfield>
      <subfield code="a">Disolventes industriales</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080628048</subfield>
      <subfield code="a">Equipos de protección individual</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080601836</subfield>
      <subfield code="a">Guantes de protección</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080566821</subfield>
      <subfield code="a">Permeabilidad</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080602574</subfield>
      <subfield code="a">Métodos de evaluación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080615543</subfield>
      <subfield code="a">Técnicas cromatográficas</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080133825</subfield>
      <subfield code="a">Hardy, James K.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">American Industrial Hygiene Association journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">American Industrial Hygiene Association journal</subfield>
      <subfield code="d">Akron, Ohio</subfield>
      <subfield code="g">Vol. 49, nº 6, June 1988 ; p. 293-300</subfield>
    </datafield>
  </record>
</collection>