Comparative testing of a FTIR remote optical sensor with area samplers in a controlled ventilation chamber
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020066</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120055.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940628e19921001usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013111</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Comparative testing of a FTIR remote optical sensor with area samplers in a controlled ventilation chamber</subfield>
<subfield code="c">M.G. Yost... [et al.]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">A portable Fourier transform infrared remote opticalsensing spectrometer was deployed and tested in a constant ventilation test chamber by using a tracer gas source. Continuous beam path measurements were collected and compared to air samples obtained from a computer-controlled, multiple-point sampling array connected to a flame ionization detector. Measurements were gathered at two defferent room ventilation rates and at two different dispersion conditions</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080616441</subfield>
<subfield code="a">Contaminación atmosférica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560997</subfield>
<subfield code="a">Ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539948</subfield>
<subfield code="a">Tests</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080582203</subfield>
<subfield code="a">Rayos infrarrojos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080568832</subfield>
<subfield code="a">Espectroscopia</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537562</subfield>
<subfield code="a">FTIR</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080591960</subfield>
<subfield code="a">Métodos de análisis</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080613655</subfield>
<subfield code="a">Control de contaminantes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080551797</subfield>
<subfield code="a">Muestreos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080584702</subfield>
<subfield code="a">Detectores ópticos</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080018467</subfield>
<subfield code="a">Yost, M.G.</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Akron, Ohio</subfield>
<subfield code="g">Vol. 53, nº 10, October 1992 ; p. 611-616</subfield>
</datafield>
</record>
</collection>