Measurements of hypergolic fuels' and oxidants' permeation through commercial protective materials. Part II : nitrogen tetroxide, monomethylhydrazine, and anhydrous hydrazine
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Sección: ArtículosTítulo: Measurements of hypergolic fuels' and oxidants' permeation through commercial protective materials. Part II : nitrogen tetroxide, monomethylhydrazine, and anhydrous hydrazine / R.N. Abernathy and S.A. GenovaAutor: Abernathy, R.N.Notas: Sumario: The authors conducted a screening study to measure breathrough times for 40 protective materials exposed to the hypergolic oxidant N2O4 and to the fuels MMH (monomethylhydrazine) and AHz (anhydrous hydrazine). Results of the study are reported in this paper and it will be considered in the selection of protective equipment and in the review of the propellant-handling procedures for Space System Division (SSD) operationsRegistros relacionados: En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 52, nº 1, January 1991 ; p. 20-29Materia / lugar / evento: Higiene industrialContaminantes químicosTetróxido de nitrógenoHidrazinasEnsayosPermeabilidadEquipos de protección individualResistencia de materialesMuestreosOtros autores: Genova, S.A. Títulos secundarios: Título: American Industrial Hygiene Association journal Otras clasificaciones: 872Derechos: In Copyright (InC)