Pesticide glove permeation analysis : comparison of the ASTM F739 test method with an automated flow-through reserve-phase liquid chromatography procedure
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020486</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120236.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940712e19900201usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013604</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080201296</subfield>
<subfield code="a">Moody, Richard P.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Pesticide glove permeation analysis</subfield>
<subfield code="b">: comparison of the ASTM F739 test method with an automated flow-through reserve-phase liquid chromatography procedure</subfield>
<subfield code="c">Richard P. Moody and Leonard Ritter</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The results of two methods of analysis for measuring glove permeability to pesticides are reported. The standard ASTM F739-85 testing procedure was used to determine breakthrough times and permeation rates for four protective glove materials for two commercially available pesticide formulations. The same glove materials and pesticides then were tested using an in-house developed automated in-vitro diffusion analysis (AIDA) procedure</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080555856</subfield>
<subfield code="a">Pesticidas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601836</subfield>
<subfield code="a">Guantes de protección</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080566821</subfield>
<subfield code="a">Permeabilidad</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080615543</subfield>
<subfield code="a">Técnicas cromatográficas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080594824</subfield>
<subfield code="a">ASTM method F-739-85</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080591960</subfield>
<subfield code="a">Métodos de análisis</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601492</subfield>
<subfield code="a">Estudios comparativos</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080145903</subfield>
<subfield code="a">Ritter, Leonard</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Akron, Ohio</subfield>
<subfield code="g">Vol. 51, nº 2, February 1990 ; p. 79-83</subfield>
</datafield>
</record>
</collection>