Búsqueda

Evaluation of solid sorbent sampling methods by breakthrough volume studies

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020521</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120248.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940715e19930201gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013639</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080100940</subfield>
      <subfield code="a">Harper, Martin</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Evaluation of solid sorbent sampling methods by breakthrough volume studies</subfield>
      <subfield code="c">Martin Harper</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">To protect the health of workers in industry, and to monitor and control the general environment, it is important to know the concentrations of chemical pollutants in the air. In this study, two porous polymer sorbents (Chromosorb 106 and Tenax TA) were used to sample a number of polar and non-polar organic solvent vapours at concentrations up to twice the OSHA PEL concentration</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080583163</subfield>
      <subfield code="a">Vapores orgánicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080616441</subfield>
      <subfield code="a">Contaminación atmosférica</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080621186</subfield>
      <subfield code="a">Control de la contaminación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080586355</subfield>
      <subfield code="a">Métodos de control</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080551797</subfield>
      <subfield code="a">Muestreos</subfield>
    </datafield>
    <datafield tag="740" ind1="4" ind2=" ">
      <subfield code="a">The Annals of occupational hygiene</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">The Annals of occupational hygiene</subfield>
      <subfield code="d">Oxford [etc.]</subfield>
      <subfield code="g">nº 1, February 1993 ; p. 65-88</subfield>
    </datafield>
  </record>
</collection>