The Design, development and assessment of electrically heated gloves used for protecting cold extremities
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020670</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120325.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940720e19880701gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013675</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">875</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080074241</subfield>
<subfield code="a">Kempson, G.E.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="4">
<subfield code="a">The Design, development and assessment of electrically heated gloves used for protecting cold extremities</subfield>
<subfield code="c">G.E. Kempson, R.P. Clark and M.R. Goff</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The design and development of electrically heated gloves for alleviating pain in vaso-spastic disorders, such a Raynaud's disease, is described. Clinical assessment of these conditions from the temperature patterns produced by infrared thermography is discussed. The effect of electrically heated gloves on tissue perfusion in individual patients can be assessed by thermography. A hot stress test to determine the degree of vaso-spasticity using the gloves to provide a hot challenge has been developed and is described</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080550653</subfield>
<subfield code="a">Ergonomía</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080628048</subfield>
<subfield code="a">Equipos de protección individual</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601836</subfield>
<subfield code="a">Guantes de protección</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560768</subfield>
<subfield code="a">Temperatura</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537555</subfield>
<subfield code="a">Frío</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080540814</subfield>
<subfield code="a">Diseño</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560799</subfield>
<subfield code="a">Termometría</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080590925</subfield>
<subfield code="a">Fenómeno de Raynaud</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080619480</subfield>
<subfield code="a">Enfermedades profesionales</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080576615</subfield>
<subfield code="a">Medicina laboral</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080022150</subfield>
<subfield code="a">Clark, R.P.</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080011567</subfield>
<subfield code="a">Goff, M.R.</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Ergonomics</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">Ergonomics</subfield>
<subfield code="d">London [etc.]</subfield>
<subfield code="g">Vol. 31, nº 7, July 1988 ; p. 1083-1091</subfield>
</datafield>
</record>
</collection>