Determination of clothing microenvironment volume
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020781</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120347.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940727e19870701gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013720</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">875</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080275389</subfield>
<subfield code="a">Sullivan, Patrick J.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Determination of clothing microenvironment volume</subfield>
<subfield code="c">Patrick J. Sullivan, Igor B. Mekjavic and Naoshi Kakitsuba</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The present study identifies some problems with the application of the Crockford and Rosenblum technique and proposes and improved method, enabling faster and more objective determinations of microenvironment volume. As a practical demonstration, the new method was used to determine microenvironment volume of four different types of helicopter pilot suits. These suits were designed primarly to provide thermal protection in the event of sudden cold water immersion, but may result in thermal stress for the wearer during normal use. Simple tests, such as assessment of microenvironment volume may aid in the choice of design and construction of such protective clothing assemblies</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080550653</subfield>
<subfield code="a">Ergonomía</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560768</subfield>
<subfield code="a">Temperatura</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080574567</subfield>
<subfield code="a">Ambiente térmico</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080571672</subfield>
<subfield code="a">Confort térmico</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539733</subfield>
<subfield code="a">Ropas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080628048</subfield>
<subfield code="a">Equipos de protección individual</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080540814</subfield>
<subfield code="a">Diseño</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560997</subfield>
<subfield code="a">Ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080562717</subfield>
<subfield code="a">Helicópteros</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080200589</subfield>
<subfield code="a">Mekjavic, Igor B.</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080196851</subfield>
<subfield code="a">Kakitsuba, Naoshi</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Ergonomics</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">Ergonomics</subfield>
<subfield code="d">London [etc.]</subfield>
<subfield code="g">Vol. 30, nº 7, July 1987 ; p. 1043-1052</subfield>
</datafield>
</record>
</collection>