Búsqueda

Electric and magnetic fields at three pulp and paper mills

Fichero PDF / PDF file
Sección: Artículos
Título: Electric and magnetic fields at three pulp and paper mills / Maria Cristina Barroetavena, Randy Ross, Kay TeschkeAutor: Barroetavena, Maria Cristina
Notas: Sumario: Extremely low frequency electric and magnetic field levels were measured at three Canadian pulp and paper mills, using area point-in-time measurements. The highest measured field was 47 V/m. Measured magnetic field strengths ranged from less than the limit of detection to 706 mG, with a median of 1.6 mG. Magnetic field levels were higher in mills that consume more electric power, but worker consumption. Overall, electric and magnetic field levels in the three pulp and paper mills were similar to those experienced by the general population. However, maximum magnetic field intensities in some areas were as high as those experienced by electrical workersRegistros relacionados: En: American Industrial Hygiene Association journal. - Fairfax, Virginia. - Vol. 55, nº 4, April 1994 ; p. 358-363Materia / lugar / evento: Higiene industrial Industria papelera Contaminación radiológica Campos electromagnéticos Enfermedades profesionales Cáncer Canadá Otros autores: Ross, Randy
Teschke, Kay
Títulos secundarios: Título: American Industrial Hygiene Association journal
Otras clasificaciones: 872