Búsqueda

A Ventilation design program for hand-held programmable computers

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071021895
003  MAP
005  20080418120605.0
007  hzruuu---uuuu
008  950302s1984 usa|||| | |00010|eng d
035  ‎$a‎6800013263
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080232993‎$a‎Shotwell, Henry P.
24512‎$a‎A Ventilation design program for hand-held programmable computers‎$c‎Henry P. Shotwell
520  ‎$a‎The computer programm allows sizing and balancing of local exhaust ventilation branches and mains using the Velocity Pressure method as described in the ACGIH Industrial Ventilation Manual. The program is written in BASIC and is designed for use in any hand-held BASIC-programmable computer such as the Radio Shack TRS-80 Pocket Computer. The user enters branch design data and the program computes duct diameter, with an override option, actual velocity, duct velocity pressure, slot velocity pressure, hood static pressure and static pressure of each branch. It will compare branch static pressures and either identify a branch to be redesigned, or will correct the flow in the branch with lower static pressure, and will call for design data for the main. It concludes with a display of the total losses at the end of the main. A complete listing of the program and a worked-out example are given
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080560997‎$a‎Ventilación
65011‎$0‎MAPA20080612597‎$a‎Sistemas de ventilación
65011‎$0‎MAPA20080608118‎$a‎Programas informáticos
65011‎$0‎MAPA20080584771‎$a‎Diseño de sistemas
65011‎$0‎MAPA20080631406‎$a‎Velocidad del incremento de presión
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 45, nº 11, 1984 ; p. 749-751