Búsqueda

Impact of fluid replacement on heat storage while wearing protective clothing

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071501952</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418123032.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">961030e20001201gbr||||    | |00010|eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080140731</subfield>
      <subfield code="a">McLellan, T. M.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Impact of fluid replacement on heat storage while wearing protective clothing</subfield>
      <subfield code="c">T. M. McLellan, S. S. Cheung</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">This study used partitional calorimetry to determine the influence of fluid replacement on heat storage during uncompensable heat stress. It was concluded that fluid replacement does not alter the rate of heat storage during uncompensable heat stress but does increase the heat storage capacity during light exercise when tolerance timer are > 60 min.</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550653</subfield>
      <subfield code="a">Ergonomía</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080565541</subfield>
      <subfield code="a">Epidemiología</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080554392</subfield>
      <subfield code="a">Fisiología</subfield>
    </datafield>
    <datafield tag="650" ind1="0" ind2="1">
      <subfield code="0">MAPA20080628048</subfield>
      <subfield code="a">Equipos de protección individual</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080568894</subfield>
      <subfield code="a">Estrés térmico</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="1">
      <subfield code="0">MAPA20080560768</subfield>
      <subfield code="a">Temperatura</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080538330</subfield>
      <subfield code="a">Calor</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080582241</subfield>
      <subfield code="a">Recintos cerrados</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080065195</subfield>
      <subfield code="a">Cheung, S. S.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Ergonomics</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Ergonomics</subfield>
      <subfield code="d">London and Washington</subfield>
      <subfield code="g">Vol. 45, nº 12, December 2000 ; p. 2020-2029.</subfield>
    </datafield>
  </record>
</collection>