Modular data logger system for physical workload measurements
<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Modular data logger system for physical workload measurements</title>
</titleInfo>
<titleInfo type="alternative">
<title>Ergonomics</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080071141">
<namePart>Hansson, G.-A</namePart>
<nameIdentifier>MAPA20080071141</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080061470">
<namePart>Asterland, P.</namePart>
<nameIdentifier>MAPA20080061470</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080074210">
<namePart>Kellerman, M.</namePart>
<nameIdentifier>MAPA20080074210</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">2003</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract>Direct technical measurements of physical workload have advantages in studies of work-related musculoskeletal disorders . A data logger has been developed, based on 20 and 40 Mbyte PCMCIA (Personal Computer Memory Card International Association) flash memory cards, for electromyography (EMG), inclinometetry and goniometry </abstract>
<note type="statement of responsibility">G.-A. Hasson, P. Asterland, M. Kellerman</note>
<note>Technical note</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080545048">
<topic>Postura</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080555337">
<topic>Movimiento</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080575755">
<topic>Electromiografía</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080570873">
<topic>Trabajo físico</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080591717">
<topic>Lesiones musculares</topic>
</subject>
<classification authority="">875</classification>
<relatedItem type="host">
<titleInfo>
<title>Ergonomics</title>
</titleInfo>
<originInfo>
<publisher>London and Washington</publisher>
</originInfo>
<part>
<text>Vol. 46, nº 4, March 2003 ; p. 407-415</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">040924</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418124826.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071505793</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>