Lutte contre le bruit dans un atelier de presses
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071016005</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418114431.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">931129e19800701fra|||| | |00010|fre d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800002239</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Lutte contre le bruit dans un atelier de presses</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Cette note donne un exemple de transformation d'un atelier de presses ayant principalement pour but d'obtenir une ambiance sonore acceptable. Au stade de la construction, les murs et le plafond ont été traités acoustiquement. Un calcul prévisionnel des niveaux sonores a permis ensuite de mettre en évidence une diminution de l'amplification due au local de l'ordre de 7,5 dB à 50 m d'une source de bruit, mais aussi une persistance d'une ambiance sonore nocive près des zones de travail, d'où la nécessité d'encoffrer les presses les plus bruyantes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080600488</subfield>
<subfield code="a">Contaminantes físicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539740</subfield>
<subfield code="a">Ruido</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080569730</subfield>
<subfield code="a">Nivel de ruido</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080579746</subfield>
<subfield code="a">Control del ruido</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080594541</subfield>
<subfield code="a">Aislamiento acústico</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080548056</subfield>
<subfield code="a">Máquinas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080545079</subfield>
<subfield code="a">Prensas</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Cahiers de notes documentaires</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">Cahiers de notes documentaires</subfield>
<subfield code="d">Paris</subfield>
<subfield code="g">nº 100, 3e. trimestre 1980 ; p. 405-413</subfield>
</datafield>
</record>
</collection>