An Evaluation of the portion diffusion sampler for long-term monitoring of halothane vapour concentrations

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017280
003  MAP
005  20080418115012.0
007  hzruuu---uuuu
008  940211s1980 gbr|||| | |00010|eng d
035  ‎$a‎6800003184
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
24513‎$a‎An Evaluation of the portion diffusion sampler for long-term monitoring of halothane vapour concentrations‎$c‎S. Kavanagh... [et al.]
520  ‎$a‎A passive sampler (Porton diffusion sampler) is evaluated for use as an indicator of halothane levels in operating rooms. The weight of halothane picked up is shown to be directly related to both ambient halothane concentration and time of exposure. However, pick up is markedly dependent on the orientation of the sampler to the gas flow and on the velocity of gas past the sampler. An equation is presented which relates weight picked up by the sampler to flow rate, halothane concentration and time