An Evaluation of the portion diffusion sampler for long-term monitoring of halothane vapour concentrations
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071017280</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115012.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940211s1980 gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003184</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="3">
<subfield code="a">An Evaluation of the portion diffusion sampler for long-term monitoring of halothane vapour concentrations</subfield>
<subfield code="c">S. Kavanagh... [et al.]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">A passive sampler (Porton diffusion sampler) is evaluated for use as an indicator of halothane levels in operating rooms. The weight of halothane picked up is shown to be directly related to both ambient halothane concentration and time of exposure. However, pick up is markedly dependent on the orientation of the sampler to the gas flow and on the velocity of gas past the sampler. An equation is presented which relates weight picked up by the sampler to flow rate, halothane concentration and time</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080616441</subfield>
<subfield code="a">Contaminación atmosférica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080613655</subfield>
<subfield code="a">Control de contaminantes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080547516</subfield>
<subfield code="a">Halotano</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080557188</subfield>
<subfield code="a">Anestésicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080565817</subfield>
<subfield code="a">Gases tóxicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080554750</subfield>
<subfield code="a">Hospitales</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080047375</subfield>
<subfield code="a">Kavanagh, S.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 2, 1980 ; p. 133-146</subfield>
</datafield>
</record>
</collection>