Measurements of the efficiency of respirator filters and filtering facepieces against radon daugther aerosols
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071018023</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115258.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940316e19921201gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800012645</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">871</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Measurements of the efficiency of respirator filters and filtering facepieces against radon daugther aerosols</subfield>
<subfield code="c">D. Wake... [et al.]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The filtration efficiencies of respirator filters and filtering facepieces have been tested against radon daughters in a fluorspar mine. The test method involved the use of sampling filters exposed to natural radon daughters in air filtered by the test respirators. Respirators with a filtration efficiency high enough for them to be considered suitable for use against toxic dusts generally reduced radon daughter levels by 90% or more, though nuisance dust masks were ineffective. The measured penetration of radon daughters through the former types of filter correlated reasonably well with the penetration of 0.1 microm netralized monodisperse aerosols, and with that of the BS 4400 sodium chloride aerosol, measured in the laboratory</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080629724</subfield>
<subfield code="a">Seguridad e higiene en el trabajo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080628048</subfield>
<subfield code="a">Equipos de protección individual</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601393</subfield>
<subfield code="a">Equipos respiratorios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080548094</subfield>
<subfield code="a">Máscaras</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080543969</subfield>
<subfield code="a">Filtros</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539658</subfield>
<subfield code="a">Radón</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080549534</subfield>
<subfield code="a">Aerosoles</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539948</subfield>
<subfield code="a">Tests</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080002770</subfield>
<subfield code="a">Wake, D.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 6, December 1992 ; p. 629-636</subfield>
</datafield>
</record>
</collection>