Quantitative analysis of asbestos minerals by the reference intensity x-ray diffraction procedure / Briant L. Davis
Sumario: X-ray diffraction analysis of asbestos-bearing materials has been completed using reference intensity ratios. The procedure includes a sample preparation method for suspension of a finely pulverized material and for deorienting the particles on a glass fiber filter. Diffraction intensities are corrected for matrix and transparency. Reference intensity ratios have been determined in this study for chrysotile, amosite, anthophyllite, crocidolite, and tremolite
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 51, nº 6, June 1990 ; p. 297-303
1. Higiene industrial . 2. Contaminantes químicos . 3. Amianto . 4. Contaminación atmosférica . 5. Control de la contaminación . 6. Difracción . 7. Métodos de análisis . 8. Muestreos . I. Título. II. Título: American Industrial Hygiene Association journal.