Búsqueda

Rayonnement infrarouge et cataractes : évaluation des risques à proximité d'un four à induction

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071023822</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120920.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">960108e19951001fra||||    | |00010|fre d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080122782</subfield>
      <subfield code="a">Barlier, Annick</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Rayonnement infrarouge et cataractes</subfield>
      <subfield code="b">: évaluation des risques à proximité d'un four à induction</subfield>
      <subfield code="c">A. Barlier, S. Salsi</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Une étude a été réalisée dans une aciérie de recyclage qui utlise un four à induction, afin d'évaluer les niveaux d'exposition dans l'infrarouge (susceptiblee de provoquer des cataractes), les risques encourus par les salriés et l'efficacité des moyens de protection. Ont été mesurés: l'éclairement énergétique entre 400 et 700 nm, à proximité de l'ouverture du four. Les facteurs de transmission spectraux des deux équipements de protection utilisés ont été mesurés entre 200 et 3000 nm. Il est montré qu'il existe un risque d'apparition de cataractes pour les personnes travaillant à proximité et dans l'environnement du four. L'écran facial comportant un dépôt métallique en surface est efficace; par contre, les lunettes munies d'un filtre vert n'assurent pas une protection suffisante</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550981</subfield>
      <subfield code="a">Fundición</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080541323</subfield>
      <subfield code="a">Hornos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080582203</subfield>
      <subfield code="a">Rayos infrarrojos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080581091</subfield>
      <subfield code="a">Lesiones oculares</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550011</subfield>
      <subfield code="a">Cataratas</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080543969</subfield>
      <subfield code="a">Filtros</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080601522</subfield>
      <subfield code="a">Evaluación de riesgos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080543815</subfield>
      <subfield code="a">Ensayos</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080055608</subfield>
      <subfield code="a">Salsi, Serge</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Cahiers de notes documentaires</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Cahiers de notes documentaires</subfield>
      <subfield code="d">Paris</subfield>
      <subfield code="g">nº 161, 4e. trimestre 1995 ; p. 469-475</subfield>
    </datafield>
  </record>
</collection>