Búsqueda

Dead space in the breathing apparatus; interaction with ventilation

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071025152
003  MAP
005  20080418121138.0
007  hzruuu---uuuu
008  960624e19950901gbr|||| | |00010|eng d
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎875
1001 ‎$0‎MAPA20080151577‎$a‎Warkander, D.E.
24510‎$a‎Dead space in the breathing apparatus; interaction with ventilation‎$c‎D.E. Warkander and C.E.G. Lundgren
520  ‎$a‎Dead space in breathing apparatus may cause increased ventilation and/or CO2 retention. Interactions between ventilation and dead space tested in the breathing apparatus of three divers: a full face mask with an oro-nasal cul (AGA), a full face mask without an oro-nasal cup (EXO-26) but designed to minimize dead space, and one mouthpiece. Comparisons of the mean inspired PCO2 to the maximum values considered acceptable by various organizations showed that the mouthpiece was always acceptable, THe AGA mask was marginally acceptable or better, while sometimes the EXO-26 was not acceptable
65011‎$0‎MAPA20080550653‎$a‎Ergonomía
65011‎$0‎MAPA20080538316‎$a‎Buceo
65011‎$0‎MAPA20080601393‎$a‎Equipos respiratorios
65011‎$0‎MAPA20080540814‎$a‎Diseño
65011‎$0‎MAPA20080560997‎$a‎Ventilación
65011‎$0‎MAPA20080564285‎$a‎Submarinismo
7001 ‎$0‎MAPA20080170042‎$a‎Lundgren, C.E.G.
7400 ‎$a‎Ergonomics
7730 ‎$t‎Ergonomics‎$d‎London and Washington‎$g‎Vol. 38, nº 9, September, 1995 ; p. 1745-1758