Pesquisa de referências

A Model for calculating the probabilities of smoke hazard from fires in multi-storey buildings

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nam a2200000 i 4500</leader>
    <controlfield tag="001">MAP20070020134</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080417181726.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940701s1992    can           00010 eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">815.1</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080302627</subfield>
      <subfield code="a">Hadjisophocleous, G.V.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="2">
      <subfield code="a">A Model for calculating the probabilities of smoke hazard from fires in multi-storey buildings</subfield>
      <subfield code="c">by G.V. Hadjisophocleous and D. Yung</subfield>
    </datafield>
    <datafield tag="260" ind1=" " ind2=" ">
      <subfield code="a">Ottawa</subfield>
      <subfield code="b">Institut de Recherche en Construction</subfield>
      <subfield code="c">[1992?]</subfield>
    </datafield>
    <datafield tag="300" ind1=" " ind2=" ">
      <subfield code="a">P. 67-80</subfield>
      <subfield code="c">28 cm</subfield>
    </datafield>
    <datafield tag="500" ind1=" " ind2=" ">
      <subfield code="a">Precede al tít.: Conseil National de Recherches Canada, Institut de Recherche en Construction</subfield>
    </datafield>
    <datafield tag="500" ind1=" " ind2=" ">
      <subfield code="a">Reprinted from Journal of Fire Protection Engineering, 4 (2) 1992, P. 67-80 (IRC Paper nº P-2079)</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">This paper presents a simplified model for calculating the probabilities of smoke hazard in multi-storey buildings. This model first establishes the fire development in a compartment on any floor, using the results from a one zone fire growth model and the computes the smoke movement in the bulding, yielding the temperature and concentration of toxic gases at any location in the bulding. The procedure used for the calculation of smoke movement, the critical time and the smoke hazard probabilities is described in this paper. Results are presented, as an example, for a twenty-five storey apartment building</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613884</subfield>
      <subfield code="a">Edificios de gran altura</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080551292</subfield>
      <subfield code="a">Incendios</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080602642</subfield>
      <subfield code="a">Modelos de simulación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080587567</subfield>
      <subfield code="a">Riesgo de incendio</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080565817</subfield>
      <subfield code="a">Gases tóxicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080538958</subfield>
      <subfield code="a">Humos</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080002930</subfield>
      <subfield code="a">Yung, D.</subfield>
    </datafield>
    <datafield tag="710" ind1="2" ind2=" ">
      <subfield code="0">MAPA20080459680</subfield>
      <subfield code="a">Institut de Recherche en Construction</subfield>
    </datafield>
    <datafield tag="856" ind1=" " ind2=" ">
      <subfield code="y">MÁS INFORMACIÓN</subfield>
      <subfield code="u">mailto:centrodocumentacion@fundacionmapfre.org?subject=Consulta%20de%20una%20publicaci%C3%B3n%20&body=Necesito%20m%C3%A1s%20informaci%C3%B3n%20sobre%20este%20documento%3A%20%0A%0A%5Banote%20aqu%C3%AD%20el%20titulo%20completo%20del%20documento%20del%20que%20desea%20informaci%C3%B3n%20y%20nos%20pondremos%20en%20contacto%20con%20usted%5D%20%0A%0AGracias%20%0A</subfield>
    </datafield>
  </record>
  <record>
    <leader>00000nxm a22000001n 4500</leader>
    <controlfield tag="001">MAPF20080176174</controlfield>
    <controlfield tag="003">MAPF</controlfield>
    <controlfield tag="004">MAP20070020134</controlfield>
    <controlfield tag="005">20080417201601.0</controlfield>
    <controlfield tag="008">0804170u    8   0001bbspa0080417</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="852" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="9">015029</subfield>
      <subfield code="p">0000015029000</subfield>
      <subfield code="h">815.1-HAD-MOD</subfield>
    </datafield>
  </record>
</collection>