Pesquisa de referências

Response of the seated human body to whole-body vertical vibration : discomfort caused by sinusoidal vibration

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Response of the seated human body to whole-body vertical vibration</title>
<subTitle>: discomfort caused by sinusoidal vibration</subTitle>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20140012107">
<namePart>Zhou, Zhen</namePart>
<nameIdentifier>MAPA20140012107</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<genre authority="marcgt">periodical</genre>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">esp</placeTerm>
</place>
<dateIssued encoding="marc">2014</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
</physicalDescription>
<abstract displayLabel="Summary">Frequency weightings for predicting vibration discomfort assume the same frequency-dependence at all magnitudes of vibration, whereas biodynamic studies show that the frequency-dependence of the human body depends on the magnitude of vibration. This study investigated how the frequency-dependence of vibration discomfort depends on the acceleration and the force at the subjectseat interface. Using magnitude estimation, 20 males and 20 females judged their discomfort caused by sinusoidal vertical acceleration at 13 frequencies (116 Hz) at magnitudes from 0.1 to 4.0 ms- 2 r.m.s. The frequency-dependence of their equivalent comfort contours depended on the magnitude of vibration, but was less dependent on the magnitude of dynamic force than the magnitude of acceleration, consistent with the biodynamic non-linearity of the body causing some of the magnitude-dependence of equivalent comfort contours. There were significant associations between the biodynamic responses and subjective responses at all frequencies in the range 116 Hz.</abstract>
<note type="statement of responsibility">Zhen Zhou, Michael J. Griffin</note>
<classification authority="">875</classification>
<relatedItem type="host">
<titleInfo>
<title>Ergonomics : the international journal of research and practice in human factors and ergonomics</title>
</titleInfo>
<originInfo>
<publisher>Oxon [United Kingdom] : Taylor & Francis, 2010-</publisher>
</originInfo>
<identifier type="issn">0014-0139</identifier>
<identifier type="local">MAP20100019818</identifier>
<part>
<text>05/05/2014 Volumen 57 Número 5 - mayo 2014 </text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">140716</recordCreationDate>
<recordChangeDate encoding="iso8601">20140724124917.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20140025626</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>