Pesquisa de referências

Tigres en cage : capotage anti-bruit

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071014985</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418114036.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">931018e19860301fra||||    | |00010|fre d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800001601</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Tigres en cage</subfield>
      <subfield code="b">: capotage anti-bruit</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Mettre un capot sur le tigre... pour supprimer les rugissements mécaniques. Ce pourrait être la divise du Service de sécurité et du C.H.S.C.T. de l'usine Sulzer de Mantes-la-Jolie. Avec les 105 db (A) émis par les deux moteurs de son banc d'essai, les opérateurs chargés de la mise au point étaient soumis à rude épreuve, sans parler des occupants des bureaux voisins. En capotant l'ensemble, l'entreprise a transformé le rugissement sauvage en un ronronnement d'animal domestique. Grâce à une cage à bruit, on a ainsi gagné 20 décibels</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080600488</subfield>
      <subfield code="a">Contaminantes físicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080539740</subfield>
      <subfield code="a">Ruido</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080579746</subfield>
      <subfield code="a">Control del ruido</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080594541</subfield>
      <subfield code="a">Aislamiento acústico</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080586485</subfield>
      <subfield code="a">Motores eléctricos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080571566</subfield>
      <subfield code="a">Casos prácticos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080639310</subfield>
      <subfield code="a">Francia</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Travail & sécurité</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20077000314</subfield>
      <subfield code="t">Travail & sécurité</subfield>
      <subfield code="d">Paris</subfield>
      <subfield code="g">nº 3, Mars 1986 ; p. 202-203</subfield>
    </datafield>
  </record>
</collection>