Pesquisa de referências

Lutte contre le bruit dans un atelier de presses

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Lutte contre le bruit dans un atelier de presses</title>
</titleInfo>
<titleInfo type="alternative">
<title>Cahiers de notes documentaires</title>
</titleInfo>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">fra</placeTerm>
</place>
<dateIssued encoding="marc">1980</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">fre</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Cette note donne un exemple de transformation d'un atelier de presses ayant principalement pour but d'obtenir une ambiance sonore acceptable. Au stade de la construction, les murs et le plafond ont été traités acoustiquement. Un calcul prévisionnel des niveaux sonores a permis ensuite de mettre en évidence une diminution de l'amplification due au local de l'ordre de 7,5 dB à 50 m d'une source de bruit, mais aussi une persistance d'une ambiance sonore nocive près des zones de travail, d'où la nécessité d'encoffrer les presses les plus bruyantes</abstract>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080600488">
<topic>Contaminantes físicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080539740">
<topic>Ruido</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080569730">
<topic>Nivel de ruido</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080579746">
<topic>Control del ruido</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080594541">
<topic>Aislamiento acústico</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080548056">
<topic>Máquinas</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080545079">
<topic>Prensas</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>Cahiers de notes documentaires</title>
</titleInfo>
<originInfo>
<publisher>Paris</publisher>
</originInfo>
<part>
<text>nº 100, 3e. trimestre 1980 ; p. 405-413</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">931129</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418114431.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071016005</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>