Pesquisa de referências

Limites de la surveillance biologique des polychlorobiphényles (P.C.B.) lors d'une exposition accidentelle

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Limites de la surveillance biologique des polychlorobiphényles (P.C.B.) lors d'une exposition accidentelle</title>
</titleInfo>
<titleInfo type="alternative">
<title>Archives des maladies professionnelles et de médecine du travail</title>
</titleInfo>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080293123">
<namePart>Sarthou-Moutengou, M.</namePart>
<nameIdentifier>MAPA20080293123</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">fra</placeTerm>
</place>
<dateIssued encoding="marc">1992</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">fre</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">A l'occasion d'une explosion non suivi d'incendie survenue sur un appareil isolé au pyralène ont été réalisées des investigations cliniques, biologiques et environnementales. Les auteurs font les observations suivantes: l'exposition liée à l'accident en ce qui concerne le pyralène et ses dérivés toxiques semble avoir été nulle; la trace d'une exposition professionnelle ancienne est mise en évidence chez le personnel électricien de l'entreprise qui ne manipule plus de pyralène depuis 1985; le taux des P.C.B. plasmatiques est, en cas d'exposition accidentelle, considéré comme un marqueur biologique d'une intoxication éventuelle par ses dérivés de thermolyse. La valeur de ce marquage semble devoir faire l'objet de réserves en ce que: chez du personnel professionnellement exposé les taux plasmátiques habituels peuvent ne pas être négligeables; la fiabilité du dosage, dont les réponses varient d'un jour à l'autre, ne semble pas parfaite</abstract>
<note type="statement of responsibility">M. Sarthou-Moutengou... [et al.]</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080576615">
<topic>Medicina laboral</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080536800">
<topic>PCB</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080613655">
<topic>Control de contaminantes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560850">
<topic>Toxicología</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080577162">
<topic>Plasma sanguíneo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080570484">
<topic>Riesgo laboral</topic>
</subject>
<subject xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080569334">
<topic>Intoxicaciones</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560973">
<topic>Valores TLV</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>Archives des maladies professionnelles et de médecine du travail</title>
</titleInfo>
<originInfo>
<publisher>Paris [etc.]</publisher>
</originInfo>
<part>
<text>nº 1, 1992 ; p. 5-11</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">930110</recordCreationDate>
<recordChangeDate encoding="iso8601">20200527152536.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071016682</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>