Effect of flanges on the velocity in front of exhaust ventilation hoods
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071017217</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418114956.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940208e19781201gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003121</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080043179</subfield>
<subfield code="a">Fletcher, B.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Effect of flanges on the velocity in front of exhaust ventilation hoods</subfield>
<subfield code="c">B. Fletcher</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The adittion of a flange to a local exhaust ventilation hood can produce a large increase in velocity in front of the hood. It is shown that an optimum flange width exists beyond which there is little further increase in velocity. As hood aspect ratio increases, the effect of flanges increases and the addition of even small flanges to slots can have an appreciables effect. Velocity increases of over 55% have been measured in front of hoods of aspect ratio 16:1</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080616441</subfield>
<subfield code="a">Contaminación atmosférica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539566</subfield>
<subfield code="a">Polvo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080552923</subfield>
<subfield code="a">Velocidad</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537210</subfield>
<subfield code="a">Aire</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560997</subfield>
<subfield code="a">Ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080612597</subfield>
<subfield code="a">Sistemas de ventilación</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 3, December 1978 ; p. 265-269</subfield>
</datafield>
</record>
</collection>