Pesquisa de referências

Suggested improvements to prevent the escape of fume from beneath the sash of a fume cupboard

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071017351</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418115024.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940214s1980    gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800003206</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080082895</subfield>
      <subfield code="a">Robertson, P.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Suggested improvements to prevent the escape of fume from beneath the sash of a fume cupboard</subfield>
      <subfield code="c">P. Robertson and P.V. Bailey</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Studies of the performance of modern aerodynamic cupboards recently installed at the University of Glasgow showed that disturbances of the air-flow caused by, for example, movement of personnel could induce escape of fume from beneath the sash lip. Modifications successfully designed to avoid this are described</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080616441</subfield>
      <subfield code="a">Contaminación atmosférica</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080621186</subfield>
      <subfield code="a">Control de la contaminación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080565954</subfield>
      <subfield code="a">Humos tóxicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080604967</subfield>
      <subfield code="a">Campanas de extracción</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080590895</subfield>
      <subfield code="a">Extracción de humos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080590888</subfield>
      <subfield code="a">Extracción de gases</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080586355</subfield>
      <subfield code="a">Métodos de control</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080037161</subfield>
      <subfield code="a">Bailey, P.V.</subfield>
    </datafield>
    <datafield tag="740" ind1="4" ind2=" ">
      <subfield code="a">The Annals of occupational hygiene</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">The Annals of occupational hygiene</subfield>
      <subfield code="d">Oxford [etc.]</subfield>
      <subfield code="g">nº 3, 1980 ; p. 305-309</subfield>
    </datafield>
  </record>
</collection>