Pesquisa de referências

Visibility of fine fibres of asbestos during routine electron microscopical analysis

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071017405</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418115039.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940216s1982    gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800003261</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080141202</subfield>
      <subfield code="a">Middleton, A.P.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Visibility of fine fibres of asbestos during routine electron microscopical analysis</subfield>
      <subfield code="c">A.P. Middleton</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Most analyses for asbestos in samples from the non-occupational environment are carried out using techniques based upon either scanning (SEM) or transmission (TEM) electron microscopy. The mode of image formation and resolution obtainable differ between SEM and TEM and the present study was undertaken in order to provide some indication of the comparability of observations made by the two techniques, with particular reference to the visibility of fine, submicrometre fibres. The results indicate that, in general, at a given magnification finer fibres are visible when using TEM than when using SEM</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080542832</subfield>
      <subfield code="a">Amianto</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613655</subfield>
      <subfield code="a">Control de contaminantes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080616441</subfield>
      <subfield code="a">Contaminación atmosférica</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080551797</subfield>
      <subfield code="a">Muestreos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080537005</subfield>
      <subfield code="a">SEM</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080537050</subfield>
      <subfield code="a">TEM</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080563387</subfield>
      <subfield code="a">Microscopios</subfield>
    </datafield>
    <datafield tag="740" ind1="4" ind2=" ">
      <subfield code="a">The Annals of occupational hygiene</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">The Annals of occupational hygiene</subfield>
      <subfield code="d">Oxford [etc.]</subfield>
      <subfield code="g">nº 1, 1982 ; p. 53-62</subfield>
    </datafield>
  </record>
</collection>