Flow-dependence of the Casella respirable-dust cyclone
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Tag | 1 | 2 | Valor |
---|---|---|---|
LDR | 00000nab a2200000 i 4500 | ||
001 | MAP20071017431 | ||
003 | MAP | ||
005 | 20080418115046.0 | ||
007 | hzruuu---uuuu | ||
008 | 940217s1983 gbr|||| | |00010|eng d | ||
035 | $a6800003287 | ||
040 | $aMAP$bspa | ||
084 | $a872 | ||
100 | 1 | $0MAPA20080030797$aOgden, T.L. | |
245 | 1 | 0 | $aFlow-dependence of the Casella respirable-dust cyclone$cT.L. Ogden, D. Barker and M.P. Clayton |
520 | $aThe penetration characteristic of the Casella respirable-dust cyclone was examined. The cyclone and a non-selective sampler were exposed to coal dust clouds, and the size distributions of the samples were measured by Coulter analysis. The work confirmed that the average equivalent spherical diameter of coal particles is close to their average aerodynamic diameter, and confirmed recent work on sampler entry efficency in calm air | ||
650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
650 | 1 | 1 | $0MAPA20080616441$aContaminación atmosférica |
650 | 1 | 1 | $0MAPA20080621186$aControl de la contaminación |
650 | 1 | 1 | $0MAPA20080607609$aPartículas ambientales |
650 | 1 | 1 | $0MAPA20080539566$aPolvo |
650 | 1 | 1 | $0MAPA20080540517$aCarbón |
650 | 1 | 1 | $0MAPA20080551797$aMuestreos |
650 | 1 | 1 | $0MAPA20080559670$aMuestreador |
700 | 1 | $0MAPA20080090708$aBarker, Donald | |
700 | 1 | $0MAPA20080065607$aClayton, M.P. | |
740 | 4 | $aThe Annals of occupational hygiene | |
773 | 0 | $tThe Annals of occupational hygiene$dOxford [etc.]$gnº 3, 1983 ; p. 261-271 |