A New generation of light-scattering instruments for respirable dust measurement
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071017674</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115134.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940307s1987 gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003081</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080090012</subfield>
<subfield code="a">Armbruster, L.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="2">
<subfield code="a">A New generation of light-scattering instruments for respirable dust measurement</subfield>
<subfield code="c">L. Armbruster</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The optical determination of respirable dust concentration by light-scattering is a suitable method for obtaining inmediate information, provided that there is a good relationship with results obtained with gravimetrical dust sampler. The Tyndallometer TM digital and its MK 2 version, the TM digital microP, have been constructed to match the definiton for respirable dust. It is a portable software-controlled instrument</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080616441</subfield>
<subfield code="a">Contaminación atmosférica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080621186</subfield>
<subfield code="a">Control de la contaminación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539566</subfield>
<subfield code="a">Polvo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080559670</subfield>
<subfield code="a">Muestreador</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080551797</subfield>
<subfield code="a">Muestreos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080586546</subfield>
<subfield code="a">Nuevas tecnologías</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080608651</subfield>
<subfield code="a">Sistemas automatizados</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 2, 1987 ; p. 181-193</subfield>
</datafield>
</record>
</collection>