The Performance of nuisance dust respirators against typical industrial aerosols
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071017696</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115139.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940307s1987 gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003081</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080158590</subfield>
<subfield code="a">Cherrie, John W.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="4">
<subfield code="a">The Performance of nuisance dust respirators against typical industrial aerosols</subfield>
<subfield code="c">J.W. Cherrie, R.M. Howie and A. Robertson</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">There are no standard test protocols available to assess the performance on nuisance dust respirators. A series of laboratory tests has been undertaken to determine the filtration efficiency and total inward leakage of a range of nuisance dust masks against a common nuisance dust. Subjective assessment of the fit and comfort of each mask was also made</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080549534</subfield>
<subfield code="a">Aerosoles</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080628048</subfield>
<subfield code="a">Equipos de protección individual</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601393</subfield>
<subfield code="a">Equipos respiratorios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080559366</subfield>
<subfield code="a">Mascarillas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080629724</subfield>
<subfield code="a">Seguridad e higiene en el trabajo</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080026363</subfield>
<subfield code="a">Howie, R.M.</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080146115</subfield>
<subfield code="a">Robertson, A.S.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 4A, 1987 ; p. 481-491</subfield>
</datafield>
</record>
</collection>