Pesquisa de referências

Entry characteristics of practical workplace aerosol samplers in relation to the ISO recommendations

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017835
003  MAP
005  20080418115214.0
007  hzruuu---uuuu
008  940309e19900601gbr|||| | |00010|eng d
035  ‎$a‎6800000001
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080209582‎$a‎Vincent, James H.
24510‎$a‎Entry characteristics of practical workplace aerosol samplers in relation to the ISO recommendations‎$c‎J.H. Vincent and D. Mark
520  ‎$a‎In recent years, new sets of criteria for health-related aerosol sampling in workplaces have been proposed by, for example, the International Standards Organizations (ISO) and the American Conference of Governmental Industrial Hygienists (ACGIH). It is therefore timely to examine the performances of workplace aerosol samplers, both instruments that have been used in the past and ones which are beginning to emerge, in the light of these recommendations. This paper describes the results and conclusions from a study of dust samplers with a view to their possible applications in the mining industry
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080549534‎$a‎Aerosoles
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080621186‎$a‎Control de la contaminación
65011‎$0‎MAPA20080559670‎$a‎Muestreador
65011‎$0‎MAPA20080555597‎$a‎Normas ISO
7001 ‎$0‎MAPA20080002015‎$a‎Mark, D.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 3, June 1990 ; p. 249-262