Comparison of asbestos air samples by SEM-EDXA and TEM-EDXA
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071018014</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115256.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940315e19920601gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800012636</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080273231</subfield>
<subfield code="a">Roberson, Kenneth T.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Comparison of asbestos air samples by SEM-EDXA and TEM-EDXA</subfield>
<subfield code="c">Kenneth T. Roberson, Thomas C. Thomas and Larry R. Sherman</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Because occupational air samples submitted to this laboratory for fibre counting often need to be confirmed as to the type of asbestos, random air samples were compared by a scanning electron microscope (SEM) and a transmission electron microscope (TEM) to determine if both methods yielded comparable resulsts. The results of this study revealed neither and advantage nor a disadvantage for confirmatory analyses of asbestos by either SEM or TEM. Several distinct characteristics were observed during the study</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080542832</subfield>
<subfield code="a">Amianto</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080551797</subfield>
<subfield code="a">Muestreos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537005</subfield>
<subfield code="a">SEM</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537050</subfield>
<subfield code="a">TEM</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537463</subfield>
<subfield code="a">EDXA</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080591960</subfield>
<subfield code="a">Métodos de análisis</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601492</subfield>
<subfield code="a">Estudios comparativos</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080208578</subfield>
<subfield code="a">Thomas, Thomas C.</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080207045</subfield>
<subfield code="a">Sherman, Larry R.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 3, June 1992 ; p. 265-269</subfield>
</datafield>
</record>
</collection>