Heat storage capacity of gelled coolants in ice vests
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071019515</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115829.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940601e19890601usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013250</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080240608</subfield>
<subfield code="a">Coleman, Sheldon R.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Heat storage capacity of gelled coolants in ice vests</subfield>
<subfield code="c">Sheldon R. Coleman</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">An experiment was designed to compare the heat storage capacity of three commercial ice vests containing gelled coolant materials to the heat storage capacity of a water-ice vest. The experimental data show that the gelled coolants tested have significantly lower heat capacities than water. The potential effect of reduced heat storage capacity on stay times in hot environments is discussed</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080600488</subfield>
<subfield code="a">Contaminantes físicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080538330</subfield>
<subfield code="a">Calor</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560768</subfield>
<subfield code="a">Temperatura</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080539733</subfield>
<subfield code="a">Ropas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080597511</subfield>
<subfield code="a">Materiales aislantes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080567149</subfield>
<subfield code="a">Refrigerantes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537555</subfield>
<subfield code="a">Frío</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Akron, Ohio</subfield>
<subfield code="g">Vol. 50, nº 6, June 1989 ; p. 325-329</subfield>
</datafield>
</record>
</collection>