Preliminary evaluation of an active end-of-service-life indicator for organic vapor Cartridge respirators

Fichero PDF / PDF file
MAP20071019979
Preliminary evaluation of an active end-of-service-life indicator for organic vapor Cartridge respirators / Ernest S. Moyer... [et al.]
Sumario: Data are presented on a microwatt chemiresistor microsensor for use with negative-pressure organic vapor respirators. This sensor would operate at or within a sorbent bed and detect parts per million levels of chemical vapors and/or gases as a function of sensor resistance
En: American Industrial Hygiene Association journal. - Fairfax, Virginia. - Vol. 54, nº 8, August 1993 ; p. 417-425
1. Higiene industrial . 2. Contaminantes químicos . 3. Vapores orgánicos . 4. Equipos respiratorios . 5. Métodos de evaluación . 6. Sensores . I. Moyer, Ernest S. . II. Título. III. Título: American Industrial Hygiene Association journal.