Pesquisa de referências

Respirator preformance rating table for mask design

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020179</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120120.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940628e19920301usa||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013481</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080221782</subfield>
      <subfield code="a">Johnson, Arthur T.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Respirator preformance rating table for mask design</subfield>
      <subfield code="c">Arthur T. Johnson, Ronald A. Weiss, Corey Grove</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">The performance rating table (PTR) is a beginning step to formulating physiological knowledge in a way that can be useful for design. The PTR organizes physiological knowledge to assign performance data to various mask and level of work causes. Best estimates of tabled values were obtained from the literature. The PTR identifies components that should become part of the eventual model, gives magnitude estimates for specific sets of conditions, and gives a basis for further work in mask design</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550653</subfield>
      <subfield code="a">Ergonomía</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080601393</subfield>
      <subfield code="a">Equipos respiratorios</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080548094</subfield>
      <subfield code="a">Máscaras</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080540814</subfield>
      <subfield code="a">Diseño</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080554392</subfield>
      <subfield code="a">Fisiología</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080182526</subfield>
      <subfield code="a">Weiss, Ronald A.</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080133160</subfield>
      <subfield code="a">Grove, Corey M.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">American Industrial Hygiene Association journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">American Industrial Hygiene Association journal</subfield>
      <subfield code="d">Akron, Ohio</subfield>
      <subfield code="g">Vol. 53, nº 3, March 1992 ; p. 193-202</subfield>
    </datafield>
  </record>
</collection>