Seção: ArtigosTítulo: The Development of a test system for investigating the performances of personal aerosol samplers under actual workplace conditions / R.A. Botham... [et al.]Notas: Sumario: This paper describes a new test system that was designed and built for this purpose. It consisted of a life-size mannequin mounted on a trolley so that it can be taken to and wheeled around in workplaces. Sampler performance should be assessed by comparing directly the aerosol collected by the sampler with that inhaled by the mannequin (and collected on filters inside the head)Registros relacionados: En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 52, nº 10, October 1991 ; p. 423-427Materia / lugar / evento: Higiene industrialContaminantes químicosAerosolesMuestreadorControl de contaminantesDiseñoTestsEquipos respiratoriosMáquinasSistemas de controlOtros autores: Botham, R.A. Títulos secundários: Título: American Industrial Hygiene Association journal Outras classificações: 872Direitos: In Copyright (InC)