Airflow pattern around a worker in a uniform freestream
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020324</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120155.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940704e19910701usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013536</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080104375</subfield>
<subfield code="a">Kim, Taehyeung</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Airflow pattern around a worker in a uniform freestream</subfield>
<subfield code="c">Taehyeung Kim, Michael R. Flynn</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The effect of boundary layer separation on worker is an important factor in the design of local exhaust ventilation. Three-dimensional airflow around a mannequin is examined by using flow visualization techniques and hot-film anemometry. Above the chest, a downwash effect is noted; from the chest to the elbows, a combination of downwash and vortex shedding is observed; and from the waist to the hip, vortex shedding appears to be dominant. A coherent vertical flow structure is observed close to the body</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080616441</subfield>
<subfield code="a">Contaminación atmosférica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080621186</subfield>
<subfield code="a">Control de la contaminación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080584412</subfield>
<subfield code="a">Corrientes de aire</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560997</subfield>
<subfield code="a">Ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080557171</subfield>
<subfield code="a">Anemómetros</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080191696</subfield>
<subfield code="a">Flynn, Michael R.</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Akron, Ohio</subfield>
<subfield code="g">Vol. 52, nº 7, July 1991 ; p. 287-296</subfield>
</datafield>
</record>
</collection>