520  ‎$a‎A complex test method for evaluating protective apparel in aerosol hazard conditions has been developed and examined under laboratory conditions. The effectiveness of the barrier or "collection efficiency" of aerosol protective apparel (APA) depends upon its structural properties such as porosity, thickness, the permeability as well as on its hydrodynamic properties, i.e., pressure drop. Aerosol generating systems and methods of measuring penetration and evaluating data are described
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080549534‎$a‎Aerosoles
65011‎$0‎MAPA20080602574‎$a‎Métodos de evaluación
65011‎$0‎MAPA20080539948‎$a‎Tests
65011‎$0‎MAPA20080566821‎$a‎Permeabilidad
65011‎$0‎MAPA20080539733‎$a‎Ropas
65011‎$0‎MAPA20080551797‎$a‎Muestreos
65011‎$0‎MAPA20080613655‎$a‎Control de contaminantes
65011‎$0‎MAPA20080537050‎$a‎TEM
65011‎$0‎MAPA20080537005‎$a‎SEM
7001 ‎$0‎MAPA20080115197‎$a‎Schoermann, J.
7001 ‎$0‎MAPA20080015480‎$a‎Opiela, H.
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 51, nº 1, January 1990 ; p. 36-43