Pesquisa de referências

Electrostatic effects in asbestos sampling II : comparison of theory and experiment

Fichero PDF / PDF file
MAP20071020484
Baron, Paul A.
Electrostatic effects in asbestos sampling II : comparison of theory and experiment / Paul A. Baron and Gregory J. Deye
Sumario: A serie of calculations was conducted to estimate the degree and type of electrostaic interactions that might occur with electrically charged asbestos samplers collecting charged particles. Relatively simple theoretical models were constructed assuming only charge-charge electrostatic interactions between a charged particle and a charge sampler. The results of these calculations were compared with some experimental measurements and the agreement between the two allowed some confidence in predicting behavior trends
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 51, nº 2, February 1990 ; p. 63-69
1. Higiene industrial . 2. Contaminantes químicos . 3. Amianto . 4. Partículas ambientales . 5. Electricidad estática . 6. Muestreador . 7. Muestreos . I. Deye, Gregory J. . II. Título. III. Título: American Industrial Hygiene Association journal.