Pesquisa de referências

Evaluation of new in-facepiece sampling procedures for full and half facepieces

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071020509
003  MAP
005  20080418120242.0
007  hzruuu---uuuu
008  940714e19930401gbr|||| | |00010|eng d
035  ‎$a‎6800013627
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080172497‎$a‎Myers, Warren R.
24510‎$a‎Evaluation of new in-facepiece sampling procedures for full and half facepieces‎$c‎W.R. Myers and R.W. Hornung
520  ‎$a‎Precision and bias were determined on five different methods of conducting in-facepiece sampling. The sampling procedures evaluated in the study were: (1) a continuous, low sampling rate, flush on the respirator, mid nose-mouth probing procedure; (2) a continuous, high sampling rate, deep front of mouth probing procedure; (3) a pulsed exhalation, deep front of mouth probing procedure; (4) an exhalation value discharge procedure; and (5) a pulsed inhalation, deep front of mouth, probing procedure
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080601393‎$a‎Equipos respiratorios
65011‎$0‎MAPA20080548094‎$a‎Máscaras
65011‎$0‎MAPA20080551797‎$a‎Muestreos
65011‎$0‎MAPA20080602574‎$a‎Métodos de evaluación
7001 ‎$0‎MAPA20080071912‎$a‎Hornung, R.W.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 2, April 1993 ; p. 151-166