Pesquisa de referências

Measurement of postural angles during work

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Measurement of postural angles during work</title>
</titleInfo>
<titleInfo type="alternative">
<title>Ergonomics</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080018658">
<namePart>Aaras, Arne</namePart>
<nameIdentifier>MAPA20080018658</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080149550">
<namePart>Stranden, Einar</namePart>
<nameIdentifier>MAPA20080149550</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1988</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">A method for continuous measurement of postural angles (head angle, arm abduction, arm flexion and back angle ) is described. The method involves attachment of potentiometer pendulums at the head, shoulder and back. In the laboratory tests the equipment ("Physiometer") seems to record the actual body angles adequately. The system is relatively simple and robust and well suited for field studies. It is planned to use the technique of postural angle measurements in the assessment of workload</abstract>
<note type="statement of responsibility">Arne Aaras and Einar Stranden</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080550653">
<topic>Ergonomía</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080557348">
<topic>Biomecánica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080545048">
<topic>Postura</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080554392">
<topic>Fisiología</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080555238">
<topic>Metrología</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080611316">
<topic>Laboratorios de ensayos</topic>
</subject>
<classification authority="">875</classification>
<relatedItem type="host">
<titleInfo>
<title>Ergonomics</title>
</titleInfo>
<originInfo>
<publisher>London [etc.]</publisher>
</originInfo>
<part>
<text>Vol. 31, nº 6, June 1988 ; p. 935-944</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940719</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120301.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071020582</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>