Pesquisa de referências

Measurement of postural angles during work

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020582</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120301.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940719e19880601gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800012720</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080018658</subfield>
      <subfield code="a">Aaras, Arne</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Measurement of postural angles during work</subfield>
      <subfield code="c">Arne Aaras and Einar Stranden</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A method for continuous measurement of postural angles (head angle, arm abduction, arm flexion and back angle ) is described. The method involves attachment of potentiometer pendulums at the head, shoulder and back. In the laboratory tests the equipment ("Physiometer") seems to record the actual body angles adequately. The system is relatively simple and robust and well suited for field studies. It is planned to use the technique of postural angle measurements in the assessment of workload</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550653</subfield>
      <subfield code="a">Ergonomía</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080557348</subfield>
      <subfield code="a">Biomecánica</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080545048</subfield>
      <subfield code="a">Postura</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080554392</subfield>
      <subfield code="a">Fisiología</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080555238</subfield>
      <subfield code="a">Metrología</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080611316</subfield>
      <subfield code="a">Laboratorios de ensayos</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080149550</subfield>
      <subfield code="a">Stranden, Einar</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Ergonomics</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Ergonomics</subfield>
      <subfield code="d">London [etc.]</subfield>
      <subfield code="g">Vol. 31, nº 6, June 1988 ; p. 935-944</subfield>
    </datafield>
  </record>
</collection>