Pesquisa de referências

An Inclinometric method for continuous measurement of sagittal movement of the lumbar spine

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020615</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120307.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940721e19880301gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800012720</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080015565</subfield>
      <subfield code="a">Otun, E.O.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="3">
      <subfield code="a">An Inclinometric method for continuous measurement of sagittal movement of the lumbar spine</subfield>
      <subfield code="c">E.O. Otun and J.A.D. Anderson</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A new inclinometric method for continuous measurement of sagittal movement of the spine in occupational or clinical studies has been developed. The method is based on miniature purpose-built inclinometers, 20mm in length, 15 mm in diameter and 17 g in weight. They are designed to be used both in the laboratory online to a microcomputer for inmediate data analysis and remotely in fields studies where their operation can be unsupervised. This paper describes the instrument and its application</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550653</subfield>
      <subfield code="a">Ergonomía</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080540814</subfield>
      <subfield code="a">Diseño</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080562847</subfield>
      <subfield code="a">Inclinómetro</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080591885</subfield>
      <subfield code="a">Medicina preventiva</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080619480</subfield>
      <subfield code="a">Enfermedades profesionales</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080579579</subfield>
      <subfield code="a">Columna vertebral</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080545048</subfield>
      <subfield code="a">Postura</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080586355</subfield>
      <subfield code="a">Métodos de control</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080153755</subfield>
      <subfield code="a">Anderson, J.A.D.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Ergonomics</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Ergonomics</subfield>
      <subfield code="d">London [etc.]</subfield>
      <subfield code="g">Vol. 31, nº 3, March 1988 ; p. 303-315</subfield>
    </datafield>
  </record>
</collection>