Nonuniform air flow in inlets : the effect on filter deposits in the fiber sampling cassette
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071021413</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120505.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">941220e19940801usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013263</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Nonuniform air flow in inlets</subfield>
<subfield code="b">: the effect on filter deposits in the fiber sampling cassette</subfield>
<subfield code="c">Paul A. Baron... [et al.]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The present study was initiated in response to an observation of nonuniform filter deposits in samplers collecting a tungsten carbide dust in an inhalation toxicology chamber. The sampler initially was used for asbestos measurements in these chambers and was applied to the tungsten carbide measurements for consistency. Such nonuniform air flow patterns in the inlet under anisoaxial conditions in combination with electrostatic, gravitational, or inertial forces</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080588946</subfield>
<subfield code="a">Ambiente de trabajo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080595074</subfield>
<subfield code="a">Carburo de tungsteno</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080575922</subfield>
<subfield code="a">Filtros químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560850</subfield>
<subfield code="a">Toxicología</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080543815</subfield>
<subfield code="a">Ensayos</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080090746</subfield>
<subfield code="a">Baron, Paul A.</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Fairfax, Virginia</subfield>
<subfield code="g">Vol. 55, nº 8, August 1994 ; p. 722-732</subfield>
</datafield>
</record>
</collection>