Pesquisa de referências

A Ventilation design program for hand-held programmable computers

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071021895</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120605.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">950302s1984    usa||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013263</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080232993</subfield>
      <subfield code="a">Shotwell, Henry P.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="2">
      <subfield code="a">A Ventilation design program for hand-held programmable computers</subfield>
      <subfield code="c">Henry P. Shotwell</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">The computer programm allows sizing and balancing of local exhaust ventilation branches and mains using the Velocity Pressure method as described in the ACGIH Industrial Ventilation Manual. The program is written in BASIC and is designed for use in any hand-held BASIC-programmable computer such as the Radio Shack TRS-80 Pocket Computer. The user enters branch design data and the program computes duct diameter, with an override option, actual velocity, duct velocity pressure, slot velocity pressure, hood static pressure and static pressure of each branch. It will compare branch static pressures and either identify a branch to be redesigned, or will correct the flow in the branch with lower static pressure, and will call for design data for the main. It concludes with a display of the total losses at the end of the main. A complete listing of the program and a worked-out example are given</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560997</subfield>
      <subfield code="a">Ventilación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080612597</subfield>
      <subfield code="a">Sistemas de ventilación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080608118</subfield>
      <subfield code="a">Programas informáticos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080584771</subfield>
      <subfield code="a">Diseño de sistemas</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080631406</subfield>
      <subfield code="a">Velocidad del incremento de presión</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">American Industrial Hygiene Association journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">American Industrial Hygiene Association journal</subfield>
      <subfield code="d">Akron, Ohio</subfield>
      <subfield code="g">Vol. 45, nº 11, 1984 ; p. 749-751</subfield>
    </datafield>
  </record>
</collection>