Pesquisa de referências

Evaluation of standard and modified sampling heads for the international PBI surface air system bioaerosol samplers

Fichero PDF / PDF file
MAP20071022854
Jensen, Paul Arthur
Evaluation of standard and modified sampling heads for the international PBI surface air system bioaerosol samplers / Paul Arthur Jensen
Sumario: Thi study substituted sampling heads with smaller holes to collect small particles with the International PBI Surface Air System (SAS) battery-powered, bioaresol air samplers, which have proved inefficient in collecting small airborne particles such as free bacteria. An Andersen six-stage (6-STG) sampler was used simultaneously with two SAS samplers to sample indoor air in two office environments
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 56, nº 3, March 1995 ; p. 272-279
1. Higiene industrial . 2. Bioaerosoles . 3. Contaminación en ambientes laborales . 4. Contaminantes biológicos . 5. Evaluación higiénica . 6. Muestreos . I. Título. II. Título: American Industrial Hygiene Association journal.