Phase contrast microscopy asbestos fiber counting performance in the proficiency analytical testing program

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071022961
003  MAP
005  20080418120802.0
007  hzruuu---uuuu
008  950712e19950501usa|||| | |00010|eng d
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080206512‎$a‎Schlecht, Paul C.
24510‎$a‎Phase contrast microscopy asbestos fiber counting performance in the proficiency analytical testing program‎$c‎Paul C. Schlecht, Stanley A. Shulman
520  ‎$a‎This report evaluates 20 years of asbestos fiber count reporting for the Proficiency Analytical Testing (PAT) program, which is operated by the American Industrial Hygiene Association (AIHA) in cooperation with the National Institute for Occupational Safety and Health (NIOSH). The PAT program is United States-based proficiency test programs that evaluate the quality of phase contrast microscope asbestos fiber counting
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080542832‎$a‎Amianto
65011‎$0‎MAPA20080565688‎$a‎Fibra mineral
65011‎$0‎MAPA20080586331‎$a‎Métodos analíticos
65011‎$0‎MAPA20080539948‎$a‎Tests
65011‎$0‎MAPA20080608095‎$a‎Programas de seguridad
65011‎$0‎MAPA20080568863‎$a‎Estados Unidos
7001 ‎$0‎MAPA20080255084‎$a‎Shulman, Stanley A.
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 56, nº 5, May 1995 ; p. 480-489