Reproducibility and stability of normalized EMG measurements on musculus trapezius
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071025914</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418121315.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">960930e19960201gbr|||| | |00010|eng d</controlfield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">875</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Reproducibility and stability of normalized EMG measurements on musculus trapezius</subfield>
<subfield code="c">Arne Aaras... [et al.]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The reliability of normalized EMGrms (root mean square value of the electromyographic signal) measurements from musculus trapezius were evaluated in a field study. The reproducibility and stability of the methods as well as the reproducibility of the results for nine variables were examined. The variables were: static, median and peak values of the ADF and the total time and number of periods when the muscle's load was below 1,2 and 5% of MVC (maximum voluntary contraction)</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080550653</subfield>
<subfield code="a">Ergonomía</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080557348</subfield>
<subfield code="a">Biomecánica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080591717</subfield>
<subfield code="a">Lesiones musculares</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080613624</subfield>
<subfield code="a">Contracciones musculares</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080545048</subfield>
<subfield code="a">Postura</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080575755</subfield>
<subfield code="a">Electromiografía</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080018658</subfield>
<subfield code="a">Aaras, Arne</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Ergonomics</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">Ergonomics</subfield>
<subfield code="d">London and Washington</subfield>
<subfield code="g">Vol. 39, nº 2, February 1996 ; p. 171-185</subfield>
</datafield>
</record>
</collection>