Pesquisa de referências

Calculs de désenfumage

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Calculs de désenfumage</title>
</titleInfo>
<titleInfo type="alternative">
<title>Face au risque</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080095659">
<namePart>Curtat, Michel</namePart>
<nameIdentifier>MAPA20080095659</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080091859">
<namePart>Bodart, Xavier</namePart>
<nameIdentifier>MAPA20080091859</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">fra</placeTerm>
</place>
<dateIssued encoding="marc">1996</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">fre</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">La fumée du feu, par sa composition chimique et sa température est une cause majeure d'atteinte à l'intégrité des personnes. Elle est responsable de plus de la moitié des décès dus au feu. Le contrôle de la fumée dans un bâtiment est ainsi un objectif essentiel pour la protection des personnes. L'utilisation de systèmes visant à l'extraire et à maintenir sa stratification au-dessus des personnes est ainsi nécessaire. Des connaissances scientifiques et des outils de caculs permettent aujourd'hui de simuler sur ordinateur l'évolution des conséquences du feu dans un bâtiment, de même que l'enfumage et son contrôle par un système naturel ou mécanique</abstract>
<note type="statement of responsibility">Michel Curtat et Xavier Bodart</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080620424">
<topic>Seguridad contra incendios</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080538958">
<topic>Humos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080575236">
<topic>Control de humos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080590833">
<topic>Evacuación de humos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080628727">
<topic>Sistemas de ventilación de humos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080602642">
<topic>Modelos de simulación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080546373">
<topic>Cálculos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080604035">
<topic>Sistemas informáticos</topic>
</subject>
<classification authority="">812.1</classification>
<relatedItem type="host">
<titleInfo>
<title>Face au risque</title>
</titleInfo>
<originInfo>
<publisher>Paris</publisher>
</originInfo>
<part>
<text>nº 328, Décembre 1996; p. 7-16</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">970407</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418121528.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071027190</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>