Pesquisa de referências

Structure acier et incendie

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Structure acier et incendie</title>
</titleInfo>
<titleInfo type="alternative">
<title>Face au risque</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080057602">
<namePart>Thomas, Loïc</namePart>
<nameIdentifier>MAPA20080057602</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">fra</placeTerm>
</place>
<dateIssued encoding="marc">1997</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">fre</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Le cas des parkings ouverts à structure acier représent un type de structure dont le comportement au feu peu varier suivant les conditions d'implantation et de mise en oeuvre. A toute ce objection, la structure en acier apporte un réponse pertinente. Ceci se traduit par un fort développement de ces constructions en Europe. Le parking à étages ouvert offre la garantie d'une évacuation des fumées et gaz chauds. De fait, la température ambiante ne s'élève pas de manière excessive et les structures n'atteignent jamais les températures critiques. On peut même ajouter qu'un plancher en bac acier collaborant est encore plus efficace car il peut retenir les éclatements du béton et donc apporter une meilleure sécurité aux équipes de secours</abstract>
<note type="statement of responsibility">Loïc Thomas</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080620424">
<topic>Seguridad contra incendios</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080544041">
<topic>Garajes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080601485">
<topic>Estructuras metálicas</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080596507">
<topic>Estructuras de acero</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080598747">
<topic>Resistencia al fuego</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080635374">
<topic>Comportamiento de los materiales frente al fuego</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080639310">
<topic>Francia</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080540975">
<topic>Europa</topic>
</subject>
<classification authority="">813.1</classification>
<relatedItem type="host">
<titleInfo>
<title>Face au risque</title>
</titleInfo>
<originInfo>
<publisher>Paris</publisher>
</originInfo>
<part>
<text>nº 336, Octobre 1997 ; p. 23-25</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">980430</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418122015.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071030081</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>